Mobile  Mobile
WebChat  WebChat

 

0086-757-88773281
huzaide@yandex.ru

语言版本     中文版     English     РУССКИЙ

keyword: Web Search:

News Center

Hunstar Chair

Your present location:HomeNewsQ / A > How should cinema chairs qualify?

How should cinema chairs qualify?

Number of visits: Date:2017-04-03 18:44:09

Cinema chair
Cinema chairs are ranked as follows:

1. Can not be fixed on the slope of the chair can not be placed on the ground.

2. Can not row of the chair can not be arranged in a curved or row to the curved site.

3. Radius is not enough to arrange the row of the site.

4. The channel is generally 1200mm,

5. Auditorium area should meet the following requirements:

A. A theater should not be less than 0.80m2 / seat;

B. B and other theaters should not be less than 0.70m2 / seat;

C. C and other theaters should not be less than 0.60m2 / seat.

6. The theater should be equipped with a fixed seat with a backrest. If the seat is not more than 12, the movable seat can be set.

7. seat armrest distance, the hard chair should not be less than 0.50m; soft chair should not be less than 0.55m.

8. Seat row spacing should meet the following requirements:

A. Short row method: the hard chair should not be less than 0.80m, soft chair should not be less than 0.90m, stepped ground row spacing should be appropriate to increase the back to the rear row of the most prominent part of the horizontal distance should not be less than 0.30m;

B. long row method: the hard chair should not be less than 1.00m; soft chair should not be less than 1.10m. Stepped ground row spacing should be appropriate to increase the back to the rear row of the most prominent part of the horizontal distance should not be less than 0.50m;

C. When setting the seat by the back wall, the last row of seats and sink seats should be increased by at least 0.12m.

9. The number of rows per row should meet the following requirements:

A. short row method: bilateral walkway should not be more than 22, unilateral walkway should not be more than 11; more than the limit, for each additional seat, row spacing increased by 25mm;

B. long row method: bilateral walkway should not exceed 50, unilateral walkway should not exceed 25 seats.

10. The audience should be reserved for disabled wheelchair seats, seats should be 1.10m, width of 0.80m, the location should facilitate the entry and evacuation of disabled persons, and should set the international common logo.

11. Slope slope is not greater than 1: 6.

12. Ramp seats can not be arranged in an arc.

13. There are horizontal walkways, the back row should not be more than 10 rows.

14. Vertical and horizontal walkways should not be less than 1.2 meters.

TypeInfo: Q / A

Keywords for the information: